Vanguard Electronic Sdn. Bhd. SEARCH




Home

Product
Automation Systems

Educational Trainers

PCB Fabrication

Test and Measuring Instruments

- B&K
- Beha
- Chekman
- Extech Instruments
- Greenlee Instruments
- Multi
- Yokogawa Measuring
  Instruments

   - 7014 Digital Oscilloscope
     DL7100

   - AC Voltage / Current      Standard
   - Compact Cal CA100
   - DAQ Station
   - Data Acquisition Unit
   - DC Calibration Sets
   - DC Voltage /      Current Standard
   - Digital Manometers
   - Digital Oscilloscopes      DL1540C & DL1540CL
   - Digital Oscilloscopes
     DL1540/DL1540 /DL1520
     /DL1520L

   - Digital Power Meters      WT110 & WT130

   - Handy Oscillographic      Recorders
   - Mini-Manometer
   - Portable DC Voltage /      Current Standard
   - Portable Hybrid Recorder
   - Power Analyzer PZ4000
   - Time Interval Analyzer      TA320
   - Time Interval Analyzer      TA520
   - uR Series Recorders

News

Buy Online

Support

About Us

Site Map



 

Home->Product-> Test & Measuring Instruments->Yokogawa Measuring Instruments->
 
 

Data Acquisition Unit - DA100

 

 

DA100

 

A streamlined DA100 is available in two version, a standalone model that can acquire data from up to 40 channels, plus an expandable model with a maximum of 300 channels. Both models transfer your measured variables, such as temperature, flow rate, strain, etc., using a new label of small size, field changeable input modules, via a general purpose communications interface (RS-232-C, RS-422A/RS-485, or GPIB, Ethernet), in realtime to a PC.

 

The DA100 is compatible with a personal computer and achieves excellent expandability and economical benefits for wide range of applications, from small-scale data logging to multipoint data acquisition.

The expandable model enables you to easily connect subunits to the main unit with a twisted pair cable. The availability of a wide variety of modules combined with simple readily adaptable construction , enables the configuration of the DA100 to be easily and quickly changed or expanded in order to meet changes in the application requirements, even in the field. The high level of user configurability the DA100 enables the user to freely configure a data acquisition environment that matches the particular application, and also effective in reducing initial investment and maintenance cost, while considering future expansion requirements.

DA100 Stand-Alone Model

Occupying little space, it is suitable for small scale data logging and can be carried about easily.

  • You can connect from 10 to 40 channels of input modules, as well as one general purpose communication module and channel alarm output modules, directly to the main unit.
  • Measurement interval : 500 ms / 40 ch minimum.

DA100 Expandable Model

The DA100 expandable model consists of the main unit, subunits and input modules. You can easily configure a multi-channel data acquisition environment by connecting the main unit to several subunits using dedicated cables.

  • The number of input channels can be increased from 10 to 300 channels in 10-channel increments.
  • Measurement interval : As fast as 500 ms.
  • Up to six subunits can be connected to one main unit, and up to six input and/or output modules can be connected to each subunits. Subunits can be separated from the main unit by up to 500 m total system cable length.

Comparison of Expandable and Stand-Alone Models

Model Data Acquisition DA100
DA100 Stand-Alone Model DA100 Expandable Model
Feature Integrated construction up to 40 channels.

Portable and suitable for small scale data logging.

Expandable up to 300 channels. Connecting subunits to the main unit, you can perform multi-channel measurement with a minimum amount of wiring
Number of input channels Expansion, change 10 to 40 channels; Channels can be added in increments of 10 channels, and the types of modules are interchangeable. 10 to 300 channels; Channels can be added in increments of 10 channels, and the types of modules are interchangeable.
Input types Voltage, temperature, contact, power, strain, pulse, direct current (mA).
Main unit I/O connections Input modules; Communications modules; DI/DO module; Alarm output module (Input module connected to the subunit); Communications module; DI/DO module; Alarm output module.
Subunit Connections, and remote measurement distance Not applicable Up to six subunits can be connected; 500m max
Subunit I/O connections Not applicable Input module; Alarm output module; DI/DO module
Extension module Available Available
Maximum scanning speed 0.5 s/all channels 0.5 s/all channels
Alarm contact output modules Main unit: 10 to 30 points Main unit: 10 to 30 points;

Subunits: 10 to 300 points

Mathematical operation channels Max. 30 channels Max. 60 channels
 


 